Sign In | Join Free | My himfr.com
Home > Power Distribution Cabinet >

90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet

Sichuan Jinhuili Electric Co., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet from wholesalers
     
    Buy cheap 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet from wholesalers
    • Buy cheap 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet from wholesalers
    • Buy cheap 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet from wholesalers
    • Buy cheap 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet from wholesalers
    • Buy cheap 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet from wholesalers

    90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet

    Ask Lasest Price
    Brand Name : Customized
    Model Number : Servo Control Cabinet
    Certification : CCC, ISO
    Price : Pending
    Payment Terms : T/T,D/A
    Supply Ability : 5000PCS/YEAR
    Delivery Time : 35 work days
    • Product Details
    • Company Profile

    90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet

    90KW pump variable frequency start control cabinet

    Key attributes

    Parameter NameParameter Value
    Rated Power90KW
    Input Voltage380V ± 10%
    Input Frequency50Hz ± 5%
    Input CurrentApproximately 170A
    Output Voltage Range0 - 380V
    Output Frequency Range0 - 400Hz
    Output Current170A
    Frequency Control Precision±0.01Hz
    Voltage Control Precision±1% of rated voltage
    Protection FunctionsOver - current protection, over - voltage protection, under - voltage protection, over - heat protection, short - circuit protection
    Communication InterfaceRS485, supporting Modbus protocol
    Operating Temperature- 10℃ to 40℃
    Storage Temperature- 20℃ to 60℃
    Humidity5% - 95%RH (non - condensing)
    Protection LevelIP54
    Mounting MethodWall - mounted or Floor - mounted
    Compatible Motor TypeThree - phase asynchronous motor
    Motor frequency conversion starting cabinet
    1. Power Parameters
    • Rated Power: 90KW, which indicates the maximum power that the control cabinet can handle to drive the motor.
    • Input Voltage: Usually, it is 380V ± 10% for three-phase input. This voltage range allows the control cabinet to adapt to certain voltage fluctuations in the power grid.
    • Input Frequency: Commonly 50Hz ± 5% or 60Hz ± 5%, depending on the regional power grid frequency.
    • Input Current: Approximately 170A under rated power conditions. This value may vary slightly according to the actual load and power factor.
    • Output Voltage Range: 0 - 380V, which can be adjusted according to the frequency variation to meet the requirements of different motor speeds.
    • Output Frequency Range: Typically 0 - 400Hz, enabling a wide range of speed regulation for the motor.
    2. Control Precision Parameters
    • Frequency Control Precision: ±0.01Hz. This high precision ensures accurate adjustment of the motor speed, which is crucial for applications that require stable speed control.
    • Voltage Control Precision: ±1% of the rated voltage. It helps maintain a stable output voltage and protect the motor from voltage fluctuations.
    3. Protection Parameters
    • Overcurrent Protection: Set at about 1.2 - 1.5 times the rated current. When the current exceeds this value, the control cabinet will take protective actions, such as cutting off the power supply, to prevent damage to the motor and the control cabinet itself.
    • Overvoltage Protection: Activated when the input or output voltage exceeds a certain threshold, usually around 110% of the rated voltage, to safeguard the electrical components.
    • Undervoltage Protection: Triggers when the voltage drops below a specific level, generally around 85% of the rated voltage, to avoid abnormal operation of the motor.
    • Overheat Protection: Monitors the temperature of key components, such as the inverter module and the motor. When the temperature reaches a preset value (e.g., 130℃ - 150℃ for the motor), the control cabinet will stop working to prevent overheating damage.
    • Short Circuit Protection: Quickly responds to short circuit faults in the circuit to isolate the fault point and protect the entire system.
    ◦ Undervoltage protection action value: Generally set to 70%-85% of the rated voltage. When the power supply voltage is lower than this value, the starting cabinet will trigger the undervoltage protection to prevent the motor from being damaged due to too low voltage.


    About The Drawing

    We have a team of experienced professionals who are responsible for carefully drawing the design drawings for every detail. To ensure that technicians can easily access key information, we have equipped each distribution cabinet with detailed drawings. These drawings are not only convenient for technicians to consult at any time, but also ensure accuracy and efficiency during operation and maintenance.

    ----After-sales service:


    Provide comprehensive pre-sales consulting and program design services.
    Provide free repair or replacement service for faults caused by product quality problems during the product warranty period.
    Provide lifelong technical support and after-sales service to ensure that customers have no worries.


    Quality 90KW Pump Variable Frequency Start Control Cabinet Frequency Inverter Control Cabinet for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sichuan Jinhuili Electric Co., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)